Re: PowerEdge R610 Memory Upgrade
Yes, you can. Place the 8gb DIMM's in slots A3,A6, B3, B6 and set the memory mode in the F2 bios to memory optimized. This should work with no errors. Regards,
View ArticleRe: how to skip "strike the f1 key to continue, f2 to run the setup utility"
What system is this? What model drive(s)?
View ArticleHard Drives in PE R310 server
The PE R310 spec sheet report that the server supports up to 8TB of internal storage and sata hard drives from 160GB to 2000GB.The question is: can I install 3TB hard drives in the server or limits set...
View ArticleRe: Hard Drives in PE R310 server
It depends on the controller ... which controller do you have?
View ArticleChange M905 Motherboard to M805
I recently purchased a K547T mother board for a Dell PowerEdge M805/M905 blade server. The motherboard is supposed to be for both servers. The basic difference between the M805 and M905 is that the...
View ArticleRe: R710 memory error after BIOS upgrade
Same here on a R610... but with just one failed DIMM (one 8GB stickout of total 48GB).Since our rig was fine before as well and just the BIOS update to 6.3.0somehow 'broke' it - I'd too suspect the new...
View ArticleRe: Installing a PCIe x16 video card into PowerEdge 2900
@kevinds, mining pretend currencty are we You don't mention where you are from but best to use Google and type "pcie wear extenders" The first couple of hits should be useful. The first hit i get is to...
View ArticleHow to connect idrac6 on server Dell poweredge r610 when i loss PIN of smart...
I using smart card authentication in idrac6. But i loss PIN of smart card so i can't connect to idrac6i try using console, telnet , ssh but i can'ti try use toll racadm with cmdwhen i type : racadm -r...
View ArticleRe: How to connect idrac6 on server Dell poweredge r610 when i loss PIN of...
You can disable Smart Card login for iDRAC in two ways1: Using Local Racadm Install OMSA on the server and run following local racadm command to disable Smart Card Login racadm config -g...
View ArticleRe: How to connect idrac6 on server Dell poweredge r610 when i loss PIN of...
i try use console, telnet , ssh but i can't.i try use cmd for remote i have error "The remote racadm interface is disable"Power button isn't signal so I can't turn on server by power button.when i plug...
View ArticleRe: Change M905 Motherboard to M805
Try flashing the board with the M805 bios to see if this will change its display: http://downloads.dell.com/published/Pages/poweredge-m805.htmlSelect drivers, then bios. Select the update that will...
View ArticleRe: Change M905 Motherboard to M805
Thanks Geoff. I already upgraded BIOS and all firmware with Dell SUU 7.3.0. M805 BIOS is at the current rev of 2.3.3.Regards,Mike
View ArticleRe: Change M905 Motherboard to M805
During POST, how is the server identified? As a M805 or M905?
View ArticleRe: Change M905 Motherboard to M805
How foolish that I did not think to look at that. It is identified as an M805. How do I get the CMC to reflect that info?
View ArticleRe: Change M905 Motherboard to M805
Perform a racadmracrest on the iDRAC for the blade and failover the CMC. This should get it to recognize the M805. Regards,
View ArticleRe: Change M905 Motherboard to M805
Geoff,Did you mean a racreset? Can I do that from the CMC CLI?Mike
View ArticleRe: Hard Drives in PE R310 server
The PERC S100 supports up to 2TB. The chipset might recognize more than 2TB with the S100 turned off, but I can't say for sure. You need an H-series with the latest firmware (H700 would be best)...
View Article