PSOD on ESX 5.1 upgrade - Could not load multiboot modules:bad parameter

$
0
0

Hello all,

 

I am receiving the pink screen of death and the error “Could not load multiboot modules:bad parameter” when trying to upgrade from ESX 4.1 to ESXi 5.1 on a Dell PowerEdge R210-II with 32 GB of RAM. According to the HCL it is supported. BIOS is running at latest supported version of 2.8.0.

 

I found the VMWare KB below but could not find any module errors in the /var/log/messages file:

ESX/ESXi driver module fails to load and reports the error: Bad parameter (1038247) | VMware KB

 

Server specs are as follows:

http://www.dell.com/downloads/global/products/pedge/spc_r210_II_new.pdf

 

Any ideas why its not working?


Solution to PCI-X on Dell Poweredge R630

$
0
0

Hi everyone, i have a Poweredge R630 server, and i need to use a LTO3 tape drive from IBM, that tape drive uses a SCSI connector, but my SCSI card(PCI-X) does not fit in the Dell Riser that comes with the server.

I need an ideia of solution.

My SCSI card does not fit in any slot of the server, does the dell  have any riser compatible with PCI-X slot? or a SCSI board low profile that fits in this server?

Anyone have a sugestion?

Regards

Jorge Aranda.

T410 Power Supply connections

$
0
0

I have T410 with a non-redundant PSU (525W). I think it has failed/failing because when I plug in the cord the fan starts and I can hear it speeding up then slowing down, and there are clicking sounds coming from (I think) inside the PSU. It's like it can't quite get going. Both of the indicator LEDs on the PSU stay dark.

1 - how can I tell for sure it is the PSU and not (for example) the fan, or some motherboard capacitor or ???

2 - I have read the hardware manual to see how to replace the PSU (see https://downloads.dell.com/manuals/all-products/esuprt_ser_stor_net/esuprt_poweredge/poweredge-t410_owner%27s%20manual_en-us.pdf page 123) and it wants me to "Disconnect all the cables from the system board and drives." Does that mean disconnect the cables from the back of the PSU but leave them connected to the other system components ... OR ... leave them connected tot he PSU and disconnect them from the other system components. In other words - do the cables come with a new PSU or not? PS - they are REALLY hard to disconnect from the back of the PSU!!!

Dell R710 Memory upgrade

$
0
0

Hi,

For r710 server that I have i've purchased a memory kit: 2 piece of 8 GB.

The current Ram config is 4 modules of 2 GB each. 

the server is dual CPU, so the memory are in A1 A2 and B1 B2.

could you please help how to arrange to dimms so it can work with all of them. 

Separately it work but not together, and i've tried different configurations.

Thanks

Can I open the case of an R710 while the power is on?

$
0
0

Want to take a look at the current memory configuration without disturbing the users.

Possible hardware/driver issue with DELL Poweredge R720

$
0
0

Hello,


We are running Red Hat Enterprise Linux 6.3 on DELL Poweredge R720 Servers. We are experiencing some issues with networking timeouts and have discovered the following information in dmesg and using lspci:


[root@hostx ~]# cat /var/log/dmesg | grep collision
pci 0000:01:00.1: address space collision: [mem 0xdc800000-0xdc83ffff pref] conflicts with 0000:01:00.0 [mem 0xdc800000-0xdc83ffff pref]
pci 0000:02:00.1: address space collision: [mem 0xdc000000-0xdc03ffff pref] conflicts with 0000:02:00.0 [mem 0xdc000000-0xdc03ffff pref]

[root@hostx ~]# lspci -v | grep Eth
01:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet PCIe
01:00.1 Ethernet controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet PCIe
02:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet PCIe
02:00.1 Ethernet controller: Broadcom Corporation NetXtreme BCM5720 Gigabit Ethernet PCIe

We are trying to determine if these messages are in any way related to the network timeout issues we are experiencing and if perhaps a firmware, bios or driver update could address the problem?


Regards,

K. Cloud

QLogic network driver installation failure

$
0
0

Hi, I am currently updating a number of R710 servers with the QLogic v20 drivers (Network_Driver_MVXGT_WN64_20.0.0_A00-00 under Server 2012 R2. The firmware has also been updated to Network_Firmware_WR5R5_WN64_08.07.25_A00-00 prior to installation of the network driver.

A number of servers have completed successfully (although there can be long delays where network connectivity is cut off whilst the driver installs) but on one particular server the installer is timing out after two hours with "The update installer operation is unsuccessful".

The log file indicates that there was some problem deleting a file, but doesn't state what file and in what location. I have tried tracing it using Procmon but it doesn't show any file system delete failures.

Is there a way to make this log more verbose so it logs every file operation during install?


The only difference on this server compared to the others is that it is not domain joined and the local administrator account has been renamed. I have tried creating a new user account with admin rights but the problem persists.

Log file:

[06/09/16 16:25:17]    Update Package Execution Started
[06/09/16 16:25:17]    Original command line: "C:\installs\Jun16\Network_Driver_MVXGT_WN64_20.0.0_A00-00.EXE"
[06/09/16 16:25:17]    DUP Framework EXE Version: 3.4.4.33
[06/09/16 16:25:17]    DUP Release: MVXGTA00-00
[06/09/16 16:25:17]    Initializing framework...
[06/09/16 16:25:17]    Data in smbios table is (hex)value = 97 , Chasis type (hex)value = 17 , System type is : Server
[06/09/16 16:25:17]    Server Infrastructure Detected...Proceeding with PM Module...
[06/09/16 16:25:17]    Querying Personality Module for data via ..GetPersonalityInfo()
[06/09/16 16:25:17]    Entered GetPersonalityInfo,Waiting for results...from PMDataCollector.lib->getPMInfo()
[06/09/16 16:25:17]    Obtained Personality Information
[06/09/16 16:25:17]    Manufacturers name :
[06/09/16 16:25:17]    Data Location :
[06/09/16 16:25:17]    Copied all Personality Information to Framework
[06/09/16 16:25:17]    Querying Personality Module Succeeded...
[06/09/16 16:25:17]    Retrieving relevant Values from Personality Module...
[06/09/16 16:25:17]    Client Brand Status:- DEFAULT
[06/09/16 16:25:17]    Brand Status DEFAULT...Header text DEFAULT
[06/09/16 16:25:18]    Brand Status DEFAULT...Image file DEFAULT
[06/09/16 16:25:18]    logo.png
[06/09/16 16:25:21]    User Command: attended
[06/09/16 16:25:21]    DUP Capabilities Value: 50331647 (0x2FFFFFF)
[06/09/16 16:25:21]    DUP Vendor Software Version: 20.0.0
[06/09/16 16:25:21]    Local System/Model Compatible with this Package? Yes
[06/09/16 16:25:21]    Local System OS Version: 6.3.0.0
[06/09/16 16:25:21]    OS Compatible with this Package? Yes
[06/09/16 16:25:21]    Local System OS Language: EN
[06/09/16 16:25:21]    Language Compatible with this Package? Yes
[06/09/16 16:25:21]    Extraction-miniunz path: C:\PROGRA~3\9FC136~1\dell\drivers\NETWOR~1.0_A\miniunz.exe
[06/09/16 16:25:21]    Extraction-arguments:  -x C:\installs\Jun16\NETWOR~2.EXE -o -d C:\PROGRA~3\9FC136~1\dell\drivers\NETWOR~1.0_A
[06/09/16 16:25:22]    Extraction-GetExitCode: 0
[06/09/16 16:25:22]    Identified Behavior : attended
[06/09/16 16:25:22]    Temporary payload log file name: C:\ProgramData\9fc136d8-fbf2-4387-8eed-ea06ff368491\dell\drivers\Network_Driver_MVXGT_WN64_20.0.0_A00-00\DUPF370.tmp
[06/09/16 16:25:22]    Translated Command Line : qlgcsetup.exe /v"LOGFILE=\"C:\ProgramData\9fc136d8-fbf2-4387-8eed-ea06ff368491\dell\drivers\Network_Driver_MVXGT_WN64_20.0.0_A00-00\DUPF370.tmp\""
[06/09/16 16:25:22]    Path : C:\ProgramData\9fc136d8-fbf2-4387-8eed-ea06ff368491\dell\drivers\Network_Driver_MVXGT_WN64_20.0.0_A00-00
[06/09/16 16:25:22]    Identified Behavior : attended
[06/09/16 18:25:22]    (DupAPI::ExecutePayload): *** Vendor Software Execute Wait Timeout Exceeded
[06/09/16 18:25:22]    Append Vendor Software Log: C:\ProgramData\9fc136d8-fbf2-4387-8eed-ea06ff368491\dell\drivers\Network_Driver_MVXGT_WN64_20.0.0_A00-00\DUPF370.tmp
[06/09/16 18:25:22]    
--- Start of Vendor Software Log ---

[06/09/16 18:25:22]    ASCII payload log file detected.
[06/09/16 18:25:22]     ============== Update Package Started ==============

 Date/Time Executed: Thu Jun 09 16:25:22 2016
 

 Command Parameters: "C:\ProgramData\9fc136d8-fbf2-4387-8eed-ea06ff368491\dell\drivers\Network_Driver_MVXGT_WN64_20.0.0_A00-00\QlgcSetup.exe" /v"LOGFILE=\"C:\ProgramData\9fc136d8-fbf2-4387-8eed-ea06ff368491\dell\drivers\Network_Driver_MVXGT_WN64_20.0.0_A00-00\DUPF370.tmp\""

 ====================================================


 Inventory version prior to update: N/A

 Update version: 18.50.4.6



[06/09/16 18:25:22]    
--- End of Vendor Software Log ---

[06/09/16 18:25:22]    Vendor Software Return Code: 259
[06/09/16 18:25:22]    (FileUtility::DeleteDirectoryTree): *** DeleteFile() has reported failure.  The error message reported by the system is:  Access is denied.
[06/09/16 18:25:22]    Brand Status DEFAULT...Image file DEFAULT
[06/09/16 18:25:22]    logo.png
[06/09/16 18:25:22]    (MUPXMLParser::GetResultName): *** Vendor Return Code is not found in Mup.xml
[06/09/16 18:25:22]    Name of Exit Code:
[06/09/16 18:25:22]    (DupAPI::GetReturnCode): *** Unable to find DUP value for:
[06/09/16 18:25:22]    Exit Code set to: 1 (0x1)
[06/09/16 18:25:22]    Result: FAILURE

Poweredge AS180 firmwware update failed

$
0
0

Hi, 

For my AS180 KVM i've tried to apply the latest firmware R173924, via RS232 cable from w2k r2 64bit.

The update returned the time-out error while upgrading; now my kvm no longer works.

I've tried running the update again and again... same error

If you have any advice.

thank you


Dell T310 stuck in boot loop

$
0
0

This morning, my Dell T310 suddenly f ailed,  Since then it has been stuck in a boot mode.  I am unable to access the bios, any of the hardware configs.   Would love to know why it f ailed suddenly and get it going.  

PowerEdge 2950 cluster problems

$
0
0

I have a solution containing 2 Power Edge 2950 servers as 2 nodes cluster operating with windows 2003 server and connected to a shared storage MD3000i via SAS connections. This solution was working correctly since 2009. a small period ago we added new Hdd's to the storage since then Node 2 cannot access the storage and the cluster doesn't fail over and the cluster service is up and running on one Node.

Could you please help. And if this solution is not supported and cannot be fixed could any body help by stating  this officially. Or how to get an official statement about this solution to provide to customer.

Dell PowerEdge R710 RAM upgrade to 96gigs using 16gig sticks

$
0
0

I've seen a couple of posts on being able to use 16gig ram sticks in an r710 with a firmware upgrade. But I am unclear on the proper installation in the three memory channels (3 per cpu). Could someone please lay it out for me? I want to purchase 96 gigs total ... 6 sticks which contain 16 gigs per stick.

CPU A                CPU B

16+16+16=48     16+16+16=48

Thanks!

Mike

PowerEdge R730xd SSD-Slots

$
0
0

Hello everybody

We have an PowerEdge R730xd Server and installed two SSDs via PCI Slot.

We have 4 Slots (2 different Cards):


1. Riser 1 - Slot2_G3_X8(CPU2)

2. Riser 1 - Slot3_G3_X8(CPU2)

3. Riser 2 - Slot4_G3_X16(CPU2)

4. Riser2 - Slot5_G3_X8(CPU1)

Does it matter in which one we install the two SSDs (performance issues..)

Thank you!

T710 memory

$
0
0

We have 8 GB memory in all slots but its only reading 120. We have tried everything with memory configuration and still not reading all memory. Please help.

Dell PowerEdge T320/T420 Internal SAS Tape Drive

$
0
0

Hello,

I am trying to install an LTO4 SAS Tape Drive into a Dell PowerEdge T320 tower server.  I have the Tape Drive and the H310 SAS Controller/HBA for connecting to the drive but I can't find the correct cable to go from the Drive to the H310.#

I was going to use P/N:  606JD which is listed at the TBU Cable for T610/T710 but not sure if that is the correct cable for this unit.

Any assistance would be massively appreciated.

Thank you

Dell Enterprise Hardware & Software Updates for June 13 - 17, 2016

$
0
0

Popular Downloads
Dell Server E-Support Tool (DSET) 3.7
Dell Support Live Image (SLI) 2.2
OpenManage Server Administrator (OMSA) 8.3
OpenManage Essentials (OME) 2.1.0
Servers & Storage
Broadcom BACS GUI and CLI application driver, family 20.2, Linux (Optional)
Broadcom NetXtreme Ethernet adapter driver, family 20.2, Windows 32-bit (Recommended)
Broadcom NetXtreme Ethernet adapter driver, family 20.2, Windows 64-bit (Recommended)
Broadcom NetXtreme Ethernet adapter RPM packaged drivers, family 19.0, Linux (Optional)
Broadcom NetXtreme Ethernet adapter, driver source files, family 20.2, Linux (Optional)
Broadcom NetXtreme network device firmware, family 20.2 (Recommended)
Broadcom NetXtreme-E Ethernet adapter driver source files, family 20.2, Linux (Recommended)
Broadcom NetXtreme-E Ethernet adapter driver, family 20.2, Windows 64-bit (Recommended)
Broadcom NetXtreme-E Ethernet adapter RPM packaged drivers, family 20.2, Linux (Recommended)
Broadcom NetXtreme-E network device firmware, family 20.2 (Recommended)
Dell OS Driver Pack (Optional)
Dell OS Driver Pack (Optional)
Dell OS Driver Pack (Optional)
Dell OS Driver Pack (Optional)
Dell PowerEdge Express Flash NVMe PCIe SSD Firmware Release (Urgent)
DELL Product DCS1410/DCSFS3500/DSS7500 add-on card Mellanox CX3 firmware (Recommended)
Delta 750W PSU (PN: 5RHVV, V1YJ6, G6W6K) Firmware Package (Recommended)
Emerson 750W PSU (PN: 0XW8W, TPJ2X) Firmware Package (Recommended)
Emulex Network and Fibre Channel Adapter Diagnostic Software. (Recommended)
Emulex Network and Fibre Channel Adapter Documentation. (Recommended)
Emulex Network and Fibre Channel Adapter Driver Disk ISO. (Recommended)
Emulex Network and Fibre Channel Adapter Drivers and Software Application. (Recommended)
Emulex Network and Fibre Channel Adapter Drivers and Software Application. (Recommended)
Emulex Network and Fibre Channel Adapter Firmware. (Recommended)
Emulex Network and Fibre Channel Adapter Software Application. (Recommended)
Emulex Network and Fibre Channel Adapter Source Code (Recommended)
Intel C220/C230/C610 Series Chipset USB 3.0 Driver (Recommended)
Intel C600/C610/C220/C230/C2000 Series Chipset Drivers (Recommended)
Intel NIC Family Version 17.5.0 Drivers for Windows 64-bit Operating Systems (Recommended)
Intel NIC Family Version 17.5.0 Firmware for I350, I354, X520, X540, and X550 adapters (Recommended)
Intel NIC Family Version 17.5.0 Linux Base Drivers - RPM Install (Recommended)
Intel NIC Family Version 17.5.0 Linux Base Drivers - Source Code Install (Recommended)
Intel NIC Family Version 17.5.0 User Guide (Optional)
Intel S3510 SSD firmware DL2B (see applicable models) (Recommended)
Intel S3610 SSD firmware DL2B (see applicable models) (Recommended)
Intel S3610 SSD firmware DL2B (see applicable models) (Recommended)
Intel S3710 SSD firmware DL2B (see applicable models) (Recommended)
Intel SSD firmware DL16 (see applicable models) (Recommended)
Lite-On 750W PSU (PN: 953MX, HTRH4, 8H33M) Firmware Package (Recommended)
Lite-On SSD firmware 11E4, Nautilus update package (see applicable models) (Recommended)
Lite-On SSD firmware 11S4, Nautilus update package (see applicable models) (Recommended)
Lite-On SSD firmware 11Y4, Nautilus update package (see applicable models) (Recommended)
Lite-On SSD firmware 11Z4, Nautilus update package (see applicable models) (Recommended)
LTO7 Webpost Firmware Package A00 (Optional)
Mellanox ESX PVSP OFED Drivers, MLNX-OFED-ESX-1.9.10.6 for Mellanox ConnectX-3, ConnectX-3 Pro adapter. These drivers support ESXi 5.5 and 6.0 (Recommended)
Microsoft Native Hotfix Driver for LTO7 Support (Optional)
OEM ID Module for R220 (Optional)
PERCCLI Utility 1.17.10 for PERC 9 controllers (Recommended)
PowerEdge C4130 system BIOS 2.1.5 (Recommended)
PowerEdge C6320 system BIOS 2.1.5 (Recommended)
PowerEdge FC430 system BIOS 2.1.5 (Recommended)
PowerEdge FC630/M630/M630 for VRTX system BIOS 2.1.6 (Recommended)
PowerEdge FC830/M830 system BIOS 2.0.3 (Recommended)
PowerEdge R230/R330/T130/T330 system BIOS 1.3.2 (Recommended)
PowerEdge R430/R530/T430 system BIOS 2.0.1 (Recommended)
PowerEdge R510 system BIOS 1.12.0 (Recommended)
PowerEdge R630/R730/R730xd system BIOS 2.1.6 (Recommended)
PowerEdge T630 system BIOS 2.1.5 (Recommended)
QLogic 32bit Windows Drivers (Recommended)
QLogic Network Adapter Windows 32-bit drivers (Recommended)
Rapid Data Common Internet File System (RDCIFS) Plug-In for DR4000/6000 series (Recommended)
Rapid Data Network File System (RDNFS) Plug-In for DR4000/6000 series (Recommended)
RDA Open Storage Technology (OST) Plugin for DR2000v/4000/6000 Series (Recommended)
RDA with NetVault (RDA) Plug-In for DR2000v/4000/6000 Series (Recommended)
Recovery and Update Utility (RUU) v2.7.184 for Dell DL Appliances (Optional)
Solaris RDA Open Storage Technology (OST) Plugin for DR2000v/4000/6000 Series (Recommended)
Utility ITDT-SE CLI (Optional)
VMware ESXi 5.5 Update 3 (Recommended)
VMware ESXi 6.0 Update 2 (Recommended)
Windows Server 2008  R2 SP1 64 bit driver for PERC S130 Controller (Recommended)
Windows Server V-Next 64-bit driver for PERC S110 Controller (Recommended)
Windows Server V-Next 64-bit driver for PERC S130 Controller (Recommended)
Networking
OpenManage Network Manager 6.2 (Recommended)
VRTX 10GbE R1-2210 network switch firmware 2.0.0.64, A03 (Recommended)
Systems Management
Dell 64-bit UEFI Diagnostics, version 4239 (Recommended)
Dell Lasso 4.7.3 (Recommended)
Dell Storage Center Operating System 6.6.5 (Recommended)
iDRAC with Lifecycle Controller, v2.30.119.30 (Recommended)
OS Updates
RHEL 6, 7 Firefox security update
RHEL 6, 7 NTP security update
RHEL 6 Kernel update
RHEL 6 spice-server security update
RHEL 6 squid security update
RHEL 6 squid34 security update

Poweredge T410 Error: POWER: unavailable in standby

$
0
0

Good afternoon!

Has anyone caught the error described below with a PowerEdge T410?

POWER: unavailable in standby

Power: Off

PowerEdge T110 usable memory

$
0
0
I have a T110 with Windows Server 2008 R2, I installed 4x 4gb pc3-10600 Ecc udimms. Bios sees 16gb, windows sees 16gb, but says only 8gb usable. I have checked the max memory boot option, tried in checking it and checking it and setting max to 16gb. I still only have 8 usable. Any advance to get all memory installed usable? Thanks

Poweredge 1550 blinking activity light.

$
0
0

So first of all yes i know this server is 14+ years old but it is a great vpn server. So i went to turn it on today and nothing came up on screen and the activity light was blinking green. Warning light was off. Any ideas? Cant find anything on google.

Slow NIC Issue on Dell R610

$
0
0

I installed Centos 7 64bit on my R610 and the NIC is slow, despite the Cisco switch set to full duplex and GigE speed. It matches the server too. I've updated the NIC driver as well, rebooted and still my speed tests using Cachefly is roughly 1MBps. It shoudl be at least 20+.

[root@server ~]# dmesg | grep "Ethernet Driver"
[    1.220806] bnx2: QLogic bnx2 Gigabit Ethernet Driver v2.2.6 (January 29, 2014)


[root@server ~]# ethtool em1
Settings for em1:
        Supported ports: [ TP ]
        Supported link modes:   10baseT/Half 10baseT/Full
                                100baseT/Half 100baseT/Full
                                1000baseT/Full
        Supported pause frame use: No
        Supports auto-negotiation: Yes
        Advertised link modes:  10baseT/Half 10baseT/Full
                                100baseT/Half 100baseT/Full
                                1000baseT/Full
        Advertised pause frame use: No
        Advertised auto-negotiation: Yes
        Speed: 1000Mb/s
        Duplex: Full
        Port: Twisted Pair
        PHYAD: 1
        Transceiver: internal
        Auto-negotiation: on
        MDI-X: off
        Supports Wake-on: g
        Wake-on: d
        Link detected: yes
        
        
[root@server ~]# ethtool -i em1
driver: bnx2
version: 2.2.6
firmware-version: 7.12.19 bc 7.10.0 NCSI 2.0.13
bus-info: 0000:01:00.0
supports-statistics: yes
supports-test: yes
supports-eeprom-access: yes
supports-register-dump: yes
supports-priv-flags: no        


[root@server ~]# mii-tool em1
em1: negotiated, link ok


---

I upgraded all drivers via OMSA / DSU using below method. I also replaced the ethernet cable with a new one just in case.


yum install srvadmin-all
/opt/dell/srvadmin/sbin/srvadmin-services.sh start
dsu -u

Memory PowerEdge R420

$
0
0

Hello all!

I want to increase the memory on the PowerEdge R420 server, because OS not used all CPU cores...

Current configuration:

 - Two processors: Intel(R) Xeon(R) CPU E5-2407

 - Two memory: 2 x 4GB (Slot: A1 and B1)


I think to buy two memories 2 x 4GB and install them to slots: A4 and B4.

But the documentations (Page 46) have string "NOTE: 16 GB quad-rank RDIMMs are not supported."? what does mean? :

Thank you for all recomendations!!!