Quantcast
Channel: PowerEdge General HW Forum - Recent Threads
Browsing all 5911 articles
Browse latest View live

Re: Dell R610 "Unsupported memory configuration" bios message

I hope i'm not too late to the party and someone will see this...I just put some additional RAM in my R610 and I'm getting this message, although I dont understand why. Here is my config:A1(16g)...

View Article


Image may be NSFW.
Clik here to view.

Re: Dell R610 "Unsupported memory configuration" bios message

It because the memory you added is mismatched to whats already in the server.For the R610 to be in "optimal" configuration, not show that error message, and get through POST without prompting F1 to...

View Article


Re: Dell R610 "Unsupported memory configuration" bios message

Interesting, thats what I was thinking about the mismatched sizes.  I do not get a POST error, and i dont have to F1 to continue, so I'm not sure that this is a huge error. I'm mostly concerned if...

View Article

Re: Dell UPS Rack/Tower 2700W and a R710 ESX 4.0 / ESXi 4.1 environment

Thank you for your answer Geoff P,So to be clear, it is not possible to have the ESX server boot up at power restoration?Are there any workarounds that you could point me to?I would like to have this...

View Article

Re: Dell R610 "Unsupported memory configuration" bios message

It could be that you have a different BIOS version than mine. That would explain why you did not get the F1 to continue.Yes there *could* be a performance decrease. Eg. in optimal mode you may get...

View Article


Re: Dell UPS Rack/Tower 2700W and a R710 ESX 4.0 / ESXi 4.1 environment

No, since the last state is OFF, so the server doesn't restart on it's  own and requires either to be restarted by the initiating a restart through the DRAC or physically starting the server.  Regards,

View Article

Image may be NSFW.
Clik here to view.

Re: T710 - Video card upgrade - Skylarking PLS Read

Hi jfnatx,sorry but i haven't been reading these forums often and missed your post. Likely you have already sorted out your PCIe graphics car What i can say is that T610 and T710 are similar in many...

View Article

Re: PowerEdge R610 citrix xenserver installation on SD card (16,32 or 64GB)

I would highly recommend not installing Xenserver or any visualization OS onto an SD card. I tried for several days to get Xenserver stable on the internal SD Card slot on a Poweredge r420 and it would...

View Article


SAS HDDs and one SATA PE2950

Hi, I've got PE2950 and Perc 5/i. 2 SAS 73 GB 15K HDDs in one array and 3 SAS 300GB 10K in second array. I decided to use one emty slot and bought 2TB SATA HDD. But I can't configure it in perc tool...

View Article


Re: SAS HDDs and one SATA PE2950

Hello matousrokosThe PERC is not capable of non-RAID. The drive will need to be in a RAID array before it can be used. The only valid configuration would be a single drive RAID 0. Go through the normal...

View Article

Re: SAS HDDs and one SATA PE2950

If what you are saying is that you can't actually configure the drive in CTRL-R (as a RAID 0) because OK is grayed out, it may be the disk you are using.  Are you using a Dell-certified drive?  An...

View Article

Image may be NSFW.
Clik here to view.

What does diagnostic service failure means?

 hi all, I know storage failure means hard drive failure but what does an exclamation mark next to diagnostic service means? When I click on that, I get another page with items having red X next to...

View Article

Re: What does diagnostic service failure means?

CallumDCan a battery be replaced without shutting down the server? The server is online & accessible but I want to double check if I should turn off the server before replacing battery.I would not...

View Article


Upgrading from xeon single to dual core in PE2800 will I also need to upgrade...

I currently have a 2800 tower with the single core xeon processor and the factory heatsink. I'm upgrading to a dual core xeon 2.8 from...

View Article

Re: PowerEdge 2900 - Windows Server 2003 R2

I guess you fixed it since we haven't heard from you. But could you please confirm what you did to fix it for archival purposes?

View Article


Re: Upgrading from xeon single to dual core in PE2800 will I also need to...

You will need these heatsinks if the previous processors were Irwindale or Nocona, since they are taller processors:TD634 Processor Heatsink Assembly Paxville Version :...

View Article

Re: Disable SSC on R815

Could anyone give an answer for my question above?

View Article


PowerEdge C1100 dead in the water...

Hello PowerEdge General HW Forum:My C1100 is in a solid fault condition. When power is applied by plugging it in, power comes on but the system is unresponsive. The power switch on the front panel is...

View Article

Re: PowerEdge C1100 dead in the water...

Inelson15,Have you taken the C1100 to a Minimum To Post configuration? This will let us know if it is being caused by something installed, or a root piece of hardware. Take everything out of the system...

View Article

Re: Upgrading from xeon single to dual core in PE2800 will I also need to...

ok, thank you, i found some on ebay for pretty cheap ($6.98 FREE shipping) Here's the link.www.ebay.com/.../360444451935

View Article
Browsing all 5911 articles