Re: 540-11148 Broadcom 5719 QP 1Gb NIC shows no iSCSI Option
I purchased this NIC for 70€ including shipping, (must be about 50USD) direct from Dell Germany. With the 5709 and 5708 DP NIC's i am able to configure all the iSCSI settings with BACS within windows....
View ArticleRe: dell poweroff problem
Hi umaraminchohan,I appreciate the time and effort that you took to troubleshoot the issue. Please let us know the details of the issue you are facing with the system after updating the BIOS.Kindly...
View ArticleRe: 540-11148 Broadcom 5719 QP 1Gb NIC shows no iSCSI Option
Thanks Daniel,i checked the CTRL S Settings.It is possible to enable iSCSI Boot and set all the Options in CTRL S Mode.But within Windows BACS only reports these offload capabilitys: LSO, CO, RSSI am...
View ArticleRe: 540-11148 Broadcom 5719 QP 1Gb NIC shows no iSCSI Option
There are licenses built into the BCOM NICs. I show that ISCSi boot is a standard option and not a licensed option on the 5719, but it is possible that the reseller of the 5719 you purchased excluded...
View ArticleRe: 540-11148 Broadcom 5719 QP 1Gb NIC shows no iSCSI Option
Thanks,the reseller is/was Dell Germany.I will check on monday with tech department.Thanks
View ArticleRe: Dell FS12 (PowerEdge C2100) Unresponsive
JCurtis-PBS,Could you power the server off, remove the power cable and then remove everything but the following from the server?Also, verify these parts are firmly installed as the system will not turn...
View ArticleRe: Upgrade Old PowerEdge SC 440
According to the specs, the Xeon 3060 is the fastest processor you can put on the Intel 3000 chipset in a PowerEdge...
View ArticleRe: Dell FS12 (PowerEdge C2100) Unresponsive
I have tried removing the ram and starting with none (to listen for error beeps) and with only 1 DIMM - with no change. I will try removing the other components.A bit more information discovered...
View ArticleRe: Dell FS12 (PowerEdge C2100) Unresponsive
Do you have redundant power supplies? Also do you have another system with known good to test with?
View ArticleRe: Dell FS12 (PowerEdge C2100) Unresponsive
I do have redundant power supplies, they both flash green when plugged in.I do not have any other systems with power supplies that have the same motherboard/mid-plane setup.
View ArticleRe: Dell FS12 (PowerEdge C2100) Unresponsive
Try each power supply alone in slot 1, then both in slot 2. Using just one at a time.
View ArticleRe: Window Server 2012 on PE2950
Just a small correction ... there is no "F6" prompt in Servers 2008/2012. Click the Load Drivers link. Also remember that the PERC does NOT support non-RAID, so if you don't first configure RAID in...
View ArticleQlogic 10GbE 2P QME8262-k Mezz
I have some questions about this mezzanine card. I opened a case on the server but noone was really familiar with this card. BTW...is there no way to post pictures on this forum. It would make...
View ArticleR710 Dell logo red instead of blue
After rebooting, the R710 is not completing POST. It is hanging just after displaying the DRAC configuration and "Press CTRL+E or wait 5 sec...". It does not respond to CTRL+E. It does respond to...
View ArticleRe: R710 Dell logo red instead of blue
Hi casl_at_cmu,The amber light on the server indicates some sort of error, there should be more information on the system LCD with an error code. You also can hold in the I button on the front of the...
View ArticleRe: R710 Dell logo red instead of blue
There are no non-green indicators. The color of the Dell BIOS logo is red, not blue, on the display. Besides the hang, that's the only odd behavior. I'll let my he guys figure it out from here.
View ArticleRe: dell poweroff problem
dell n5110 does not hibernate or turn off when i give the command. when i give the command a black screen appears and the power button light remain on,. this occure after updating the bios.
View ArticleRe: dell poweroff problem
Hi umaraminchohan,Thanks for providing us this information. Please let us know which command you use to put the system to hibernate or sleep.Also, let us know if system was shipped with Windows 8 or...
View ArticleRe: Unable to ping BMC, iDRAC on R410.
I don't believe the management controller needs to be activated on the NIC's. This outside the typical activity of our NIC's. What switches are your connected to? We have seen switch configurations...
View ArticleRe: PER510 BIOS/FW UPDATE FAILS
We use the DELL Repository Manager to create our own SUU Updates disks. With it you can specify what you want written to the SUU ISO, either platform or component specific. That way you will be able...
View Article